Research1 min read

EFFECT OF BEVEL DIRECTION ON THE SUCCESS RATE OF ULTRASOUND-GUIDED RADIAL ARTERIAL CATHETERIZATION

On this page

Key points

  • Bevel-down orientation gave more first-attempt successes than bevel-up (84.3% vs 71.6%, p = 0.028).
  • Cannulation was faster with bevel-down (mean 33.3 s vs 35.9 s, p = 0.011).
  • Posterior wall puncture occurred less often with bevel-down (11 vs 22 patients).
Study at a glance
Design
Randomised comparison
Participants
204 (102 per group)
Comparison
Bevel-down vs bevel-up
First-attempt success
84.3% vs 71.6%
Mean cannulation time
33.3 s vs 35.9 s
Posterior wall puncture
11 vs 22 patients

Background

This study assessed the effect of bevel direction on the success rate of ultrasound guided radial artery catheterization.

Methods

A total of 204 patients requiring radial artery catheterization were randomly divided into bevel-up (n = 102) and bevel-down (n = 102) groups. Success rate, cannulation time, and number of attempts were compared groups.

Results

In the bevel-down group, an arterial line was placed on the first attempt in 86 of 102 (84.3 %; 95 % confidence interval [CI] = 76 % to 90 %) patients versus 73 of 102 (71.6 %; 95 % CI = 62.1 % to 79.4 %) in the bevel-up group (p = 0.028). In the bevel-down group, the mean time to a successful radial arterial cannulation was 33.3 ± 6.3 seconds (95 % CI = 32.1-34.6) versus 35.9 ± 7.6 seconds (95 % CI = 34.4-37.2) in the bevel-up group (p = 0.011). The median score was 33.2 and interquartile range [IQR] was 10.9 (30.3-41.2) for the mean cannulation time in the bevel-up group. In the bevel-down group, the mean score was 32.3 (IQR 3.90, 30–33.9) for mean cannulation time. In the bevel-down group, 11 of 102 (7 %; 95 % CI = 0 to 16 %) patients developed a posterior wall puncture versus 22 of 102 ((21.6 %; 95 % CI = 14.7 to 17.2 %) in the bevel-up group.

Conclusion

The bevel-down approach during ultrasound-guided radial artery catheterization exhibited a higher success with fewer complications compared to the bevel-up approach.

How to cite

Min S. W., Cho H. R., Jeon Y. T. et al. EFFECT OF BEVEL DIRECTION ON THE SUCCESS RATE OF ULTRASOUND-GUIDED RADIAL ARTERIAL CATHETERIZATION. BMC Anesthesiology. 2016;16:34. doi:10.1186/s12871-016-0202-5

Study at a glance
Design
Randomised comparison
Participants
204 (102 per group)
Comparison
Bevel-down vs bevel-up
First-attempt success
84.3% vs 71.6%
Mean cannulation time
33.3 s vs 35.9 s
Posterior wall puncture
11 vs 22 patients
Source
BMC Anesthesiology
doi.org/10.1186/s12871-016-0202-5
Open at the journal
LEARN THIS SKILL
Focused Cardiac Ultrasound (FoCUS) Workshop
GuidelineSUCCES faculty
SUCCES Malaysia · SUCCES recommendation